THERE ARE 3 POSSIBLE ELECTRICAL CONTROL CONFIGURATIONS FOR THIS OPERATOR:
A) Standard relay logic controls (not UL325 2010 compliant, not available in US). Refer to Section A for electrical
connections. Refer to electrical drawings inside your operator control box or generic drawings MS100-WW or
MS300-WW in the electrical drawings section at the end of this manual.
B) Relay logic controls with Interface Module (UL325 (2010) compliant. Refer to Section B for electrical
connections. Refer to electrical drawings inside your operator control box or generic drawings MS100-IM-WW or
MS300-IM-WW in the electrical drawings section at the end of this manual.
C) Full Feature logic board Smart 10.0 (UL325 (2010) compliant). Refer to Section C for electrical
Connections and logic board instructions. Refer to electrical drawings inside your operator control box or generic
drawings MSL100-110V-WW, MSL100-220V-WW, MSL300-WW or MSLC300-WW in the electrical drawings
section at the end of this manual.
Refer to electrical diagrams inside control box cover or at the end of this manual prior to connection of power supply or
control station.
WARNING
TO REDUCE THE RISK OF INJURY OR DEATH:
ALL ELECTRICAL CONNECTIONS SHOULD BE MADE BY A QUALIFIED SERVICE PERSON
DO NOT ATTEMPT TO MAKE ELECTRICAL CONNECTIONS TO OPERATOR UNLESS POWER SUPPLY HAS
BEEN DISCONNECTED AT FUSE BOX
OPERATOR MUST BE CONNECTED IN ACCORDANCE TO LOCAL ELECTRICAL CODES AND GROUNDED
TO GREEN GROUND LUG LOCATED INSIDE CONTROL BOX
WARNING
COMPARE AVAILABLE POWER SUPPLY VOLTAGE TO OPERATOR NAMEPLATE PRIOR TO ELECTRICAL
CONNECTION. FAILURE TO CONNECT APPROPRIATE POWER SUPPLY VOLTAGE MAY CAUSE SERIOUS
DAMAGE TO OPERATOR.
IMPORTANT
- MICANAN HIGHLY RECOMMENDS THAT EACH INDIVIDUAL COMMERCIAL DOOR OPERATOR
HAVE IT’S OWN DEDICATED POWER SUPPLY
- MICANAN HIGHLY RECOMMENDS THAT EACH INDIVIDUAL COMMERCIAL DOOR OPERATOR
HAVE AN EXTERNAL CIRCUIT BREAKER OR FUSED DISCONNECT
Comments to this Manuals