SECTION E: For Operators with Interface Modules or Logic boards
Installation Safety Precautions
WARNING: MICANAN MK00649 NEMA-1 infrared photo system is for use only with MICANAN logic board operators
or relay logic operators equipped with the Micanan failsafe interface module. Use of this device on other than
recommended operators can lead to severe or fatal injury. Follow these instructions carefully.
IMPORTANT: For momentary activation on close, the MICANAN photobeams (or a Micanan 2-wire monitored edge),
must be installed as part of the operator system. If a Micanan 2-wire monitored edge or the MICANAN infrared
photobeam system is not installed (or not operating correctly), the operator will only operate in fault mode
(constant pressure to close).
READ and FOLLOW all installation instructions.
1. Before installing the photo beam, read the door or gate operator’s instruction manual fully, so you are aware of all of
the unit’s functions and features.
2. Wear protective gloves and eye protection when using tools.
3. Before installing photo beam, disconnect all power to door operator to prevent unintended operation and have the
door full open or close.
4. Do not reconnect power to the door or gate operator until instructed to do so.
5. Only install photobeams on a properly functioning door or gate operator.
6. Installation and wiring must comply with local building and electrical codes. This device is not intended and must not
be installed in a explosive environment.
WARNING: Keep fingers and other body parts away from all moving parts of the door and gate operator system
while the system is being operated.
WARNING: To prevent unintended operation, disconnect power to the door or gate operator prior to installing the
photobeam system.
MICANAN N-1 PHOTOCELL (MK00649)
Installation
Note: Photo beams should be mounted as close to the door track inside the door to offer maximum entrapment
protection.
Wall installation:
1. Select a location on the wall no more than 6 inches from the floor to install wall mounting brackets on the left and
right side of the door. Both brackets must be mounted at the same height for proper alignment.
2. Drill holes in the wall and attach brackets to the wall using screws and nails provided as shown in Fig. 1.