10
SECTION A: PRO-J, PRO-H Standard relay logic controls (not UL325 2010
compliant, not available in US)
POWER WIRING: Use 1-1/8” (2.85 cm) diameter holes for all power wiring.
1. Single phase: Connect single phase power supply to terminals L/L1 (line) and N/L2 on three-pole
power terminal strip.
2. Three-phase: Connect three phase power supply to terminals L1, L2 and L3 on three-pole power
terminal strip.
CONTROL WIRING: Use 7/8” (2.22 cm) diameter holes for all control wiring.
Note: Do not run control wires and power wires in same conduit.
- Install control station within clear sight of door but away from all moving parts of door or hardware.
Install Entrapment warning sign next to control station. Connect 3-button (open/close/stop) push button
station to terminals 2, 3, 4 and 5. Refer to electrical diagram for connection of two 3-button stations.
NOTE: After electrical connections are made, manually move door to mid-position and, using the control station press the
“Open” button for several seconds and then press the “Stop” button. If door did not move in correct direction verify
wiring control station. For 3-phase operators, if door still moves in wrong direction reverse any two of the three
incoming power supply leads to correct rotation.
- Adjust Limit switches as explained in the “Limit switch adjustment section” further in this manual.